Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	31
Date	08/07/14
Start Time	16:00:13
Diameter Midpoint
 11.3	718263
 11.8	737442
 12.2	757627
 12.6	782482
 13.1	802249
 13.6	834154
 14.1	856988
 14.6	871956
 15.1	889670
 15.7	896905
 16.3	906850
 16.8	894242
 17.5	880791
 18.1	856979
 18.8	833219
 19.5	794170
 20.2	739726
 20.9	689899
 21.7	617608
 22.5	548548
 23.3	468974
 24.1	387467
 25.0	314381
 25.9	248929
 26.9	191252
 27.9	143873
 28.9	105367
 30.0	76959.7
 31.1	54182.3
 32.2	38668.6
 33.4	27843.8
 34.6	19160.3
 35.9	14523.4
 37.2	12333.3
 38.5	10397.7
 40.0	9572.11
 41.4	9343.7
 42.9	8997.39
 44.5	9091.64
 46.1	8863.62
 47.8	9665.36
 49.6	10592.1
 51.4	10768.4
 53.3	9798.86
 55.2	8400.86
 57.3	7356.25
 59.4	5675.46
 61.5	4633.57
 63.8	3543.32
 66.1	2669.1
 68.5	1976.17
 71.0	1466.44
 73.7	1176.53
 76.4	842.111
 79.1	713.681
 82.0	514.106
 85.1	431.278
 88.2	375.79
 91.4	292.018
 94.7	256.636
 98.2	184.606
101.8	182.921
105.5	151.254
109.4	89.1075
113.4	73.983
117.6	78.8551
121.9	75.2688
126.3	55.9876
131.0	70.4704
135.8	43.3725
140.7	48.4575
145.9	37.784
151.2	41.9488
156.8	31.482
162.5	33.584
168.5	29.2801
174.7	28.5503
181.1	44.5001
187.7	40.6435
194.6	21.6821
201.7	24.1877
209.1	29.1712
216.7	27.5404
224.7	30.5887
232.9	14.9803
241.4	27.9377
250.3	18.3551
259.5	15.0139
269.0	11.4429
278.8	10.8875
289.0	26.1763
299.6	22.4892
310.6	14.5423
322.0	9.97773
333.8	33.5653
346.0	23.3312
358.7	12.947
371.8	1.73463
385.4	12.1629
399.5	4.00522
414.2	9.03471
429.4	9.58654
445.1	9.51714
461.4	3.64173
478.3	13.6163
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6869
High Voltage	9933.27
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	16.5657
Mean(nm)	17.5608
Geo. Mean(nm)	16.9123
Mode(nm)	16.2531
Geo. Std. Dev.	1.30079
Total Concentration(#/cm)	1.81529e+007
Comment	
